Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57.420
Filter
1.
Biomed Microdevices ; 26(2): 21, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38558326

ABSTRACT

Kirigami is one of the interesting paper art forms and the modified sub-class of origami. Kirigami paper art is widely employed in a variety of applications, and it is currently being used in biosensors because of its outstanding advantages. This is the first study on the use of a Kirigami-based aptasensor for DENV (Dengue virus)-antigen detection. In this study, the kirigami approach has been utilized to develop a stretchable, movable, and flexible sensor. The constructed stretchable-kirigami electrode helps in adjusting the connection of electrodes without disturbing the electrochemical cell zone during the experiment. To increase the sensitivity of this biosensor we have synthesized Ag-NPs (Silver nanoparticles) via chemical methods and characterized their results with the help of TEM & UV-Vis Spectroscopy. Different electrochemical approaches were used to validate the sensor response i.e., CV (Cyclic voltammetry) and LSV (Linear sweep voltammetry), which exhibited great detection capability towards dengue virus with the range of 0.1 µg/ml to 1000 µg/ml along with a detection limit of 0.1 µg/ml and showing no reactivity to the chikungunya virus antigen, making it more specific to the DENV antigen. Serum (healthy-human) was also successfully applied to validate the results of the constructed aptasensor. Integration of the Kirigami approach form with the electrochemical aptasensor that utilizes a 3-E setup (three-electrode setup) which is referred to as a tripod and collectively called Kirigami-tripod-based aptasensor. Thus, the developed integrated platform improves the sensors capabilities in terms of cost efficiency, high stretchability, and sensitivity.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Dengue , Metal Nanoparticles , Humans , Metal Nanoparticles/chemistry , Electrochemical Techniques/methods , Aptamers, Nucleotide/chemistry , Gold/chemistry , Silver/chemistry , Biosensing Techniques/methods , Electrodes , Dengue/diagnosis , Limit of Detection
2.
Anal Chem ; 96(14): 5446-5454, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38556805

ABSTRACT

In this study, a novel integrated photoelectrochemical (PEC) sensor platform was proposed, utilizing an optical fiber (OF) as the working electrode for guided in situ light. A CdS quantum dots (QDs)/ZnO nanosheets (NSs) n-n heterojunction was quickly and easily constructed on the OF surface by successive ionic layer adsorption and reaction (SILAR). Au nanoparticles (NPs)@dsDNA as a capturing probe were modified on the CdS QDs/ZnO NSs@OF (CZ@OF). Due to the energy transfer between Au NPs@dsDNA and CdS QDs, the resultant opto-electrode has a lower background near zero, enabling the "signal-on" detection of biomarkers (interleukin-6 (IL-6) as a model). The OF-PEC biosensor demonstrated a wide linear range from 1 to 100 pg mL-1 with a regression coefficient (R2) of 0.9958 and an impressive detection limit (LOD) of 0.19 pg mL-1. More significantly, the proposed OF-PEC can be successfully used for the detection of IL-6 in serum samples from patients with pulmonary arterial hypertension, and it showed consistency and is more sensitive to trace concentrations compared to BD FACSCanto II flow cytometry used at the hospital. This holds significance for an early disease diagnosis. Therefore, the proposed OF-PEC not only achieves integration of the light source and sensing interface but also enables sensitive and accurate "signal-on" detection of IL-6. Furthermore, due to the flexibility and remote detection capabilities of OF, the application of OF-PEC is expected to be expanded more widely. This approach opens up possibilities for advances in PEC sensing.


Subject(s)
Biosensing Techniques , Metal Nanoparticles , Quantum Dots , Zinc Oxide , Humans , Electrochemical Techniques , Cytokines , Interleukin-6 , Gold , Adsorption , Optical Fibers , Electrodes , Limit of Detection
3.
ACS Appl Mater Interfaces ; 16(14): 17219-17231, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38561895

ABSTRACT

Herein, we demonstrate the detection of glucose in a noninvasive and nonenzymatic manner by utilizing an extended gate field-effect transistor (EGFET) based on the organic molecule pyrene phosphonic acid (PyP4OH8) incorporated nickel metal-organic framework (NiOM-MOF). The prepared electrode responds selectively to glucose instead of sucrose, fructose, maltose, ascorbic acid, and uric acid in a 1× phosphate buffer saline solution. Also, utilizing the scanning Kelvin probe system, the sensing electrode's work function (Φ) is measured to validate the glucose-sensing mechanism. The sensitivity, detection range, response time, limit of detection, and limit of quantification of the electrode are determined to be 24.5 µA mM-1 cm-2, 20 µM to 10 mM, less than 5 s, 2.73 µM, and 8.27 µM, respectively. Most interestingly, the developed electrode follows the Michaelis-Menten kinetics, and the calculated rate constant (km) 0.07 mM indicates a higher affinity of NiOM-MOF toward glucose. The real-time analysis has revealed that the prepared electrode is sensitive to detect glucose in real human saliva, and it can be an alternative device for the noninvasive detection of glucose. Overall, the outcomes of the EGFET studies demonstrate that the prepared electrodes are well-suited for expeditious detection of glucose levels in saliva.


Subject(s)
Diabetes Mellitus , Metal-Organic Frameworks , Humans , Glucose/analysis , Electrodes , Pyrenes
4.
ACS Appl Bio Mater ; 7(4): 2488-2498, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38577953

ABSTRACT

Green synthesis approaches for making nanosized ceria using starch from cassava as template molecules to control the particle size are reported. The results of the green synthesis of ceria with an optimum calcination temperature of 800 °C shows a size distribution of each particle of less than 30 nm with an average size of 9.68 nm, while the ratio of Ce3+ to Ce4+ was 25.6%. The green-synthesized nanoceria are applied to increase the sensitivity and attach biomolecules to the electrode surface of the electrochemical aptasensor system for coronavirus disease (COVID-19). The response of the aptasensor to the receptor binding domain of the virus was determined with the potassium ferricyanide redox system. The screen-printed carbon electrode that has been modified with green-synthesized nanoceria shows 1.43 times higher conductivity than the bare electrode, while those modified with commercial ceria increase only 1.18 times. Using an optimized parameter for preparing the aptasensors, the detection and quantification limits were 1.94 and 5.87 ng·mL-1, and the accuracy and precision values were 98.5 and 89.1%. These results show that green-synthesized ceria could be a promising approach for fabricating an electrochemical aptasensor.


Subject(s)
Biosensing Techniques , COVID-19 , Cerium , Manihot , Nanoparticles , Carbon/chemistry , SARS-CoV-2 , Electrochemical Techniques/methods , Biosensing Techniques/methods , COVID-19/diagnosis , Nanoparticles/chemistry , Electrodes
5.
Biofabrication ; 16(3)2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38574551

ABSTRACT

Conventional gut-on-chip (GOC) models typically represent the epithelial layer of the gut tissue, neglecting other important components such as the stromal compartment and the extracellular matrix (ECM) that play crucial roles in maintaining intestinal barrier integrity and function. These models often employ hard, flat porous membranes for cell culture, thus failing to recapitulate the soft environment and complex 3D architecture of the intestinal mucosa. Alternatively, hydrogels have been recently introduced in GOCs as ECM analogs to support the co-culture of intestinal cells inin vivo-like configurations, and thus opening new opportunities in the organ-on-chip field. In this work, we present an innovative GOC device that includes a 3D bioprinted hydrogel channel replicating the intestinal villi architecture containing both the epithelial and stromal compartments of the gut mucosa. The bioprinted hydrogels successfully support both the encapsulation of fibroblasts and their co-culture with intestinal epithelial cells under physiological flow conditions. Moreover, we successfully integrated electrodes into the microfluidic system to monitor the barrier formation in real time via transepithelial electrical resistance measurements.


Subject(s)
Hydrogels , Lab-On-A-Chip Devices , Electric Impedance , Epithelial Cells , Electrodes
6.
J Environ Manage ; 357: 120823, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38583380

ABSTRACT

Fe(II) regeneration plays a crucial role in the electro-Fenton process, significantly influencing the rate of ·OH formation. In this study, a method is proposed to improve Fe(II) regeneration through N-doping aimed at enhancing the adsorption capacity of the activated carbon cathode for Fe(III). N-doping not only enriched the pore structure on the surface of activated carbon, providing numerous adsorption sites, but also significantly increased the adsorption energy for Fe(III). Among the types of nitrogen introduced, pyridine-N exhibited the most substantial enhancement effect, followed by pyrrole-N, while graphite-N showed a certain degree of inhibition. Furthermore, N-doping facilitated the adsorption of all forms of Fe(III) by activated carbon. The adsorption and electrosorption rates of the NAC-900 electrode for Fe(III) were 30.33% and 42.36%, respectively. Such modification markedly enhanced the Fe3+/Fe2+ cycle within the electro-Fenton system. The NAC-900 system demonstrated an impressive phenol degradation efficiency of 93.67%, alongside the lowest electricity consumption attributed to the effective "adsorption-reduction" synergy for Fe(III) on the NAC-900 electrode. Compared to the AC cathode electro-Fenton system, the degradation efficiency of the NAC-900 cathode electro-Fenton system at pH = levels ranging from 3 to 5 exceeded 90%; thus, extending the pH applicability of the electro-Fenton process. The degradation efficiency of phenol using the NAC-900 cathode electro-Fenton system in various water matrices approached 90%, indicating robust performance in real wastewater treatment scenarios. This research elucidates the impact of cathodic Fe(III) adsorption on Fe(II) regeneration within the electro-Fenton system, and clarifies the influence of different N- doping types on the cathodic adsorption of Fe(III).


Subject(s)
Ferric Compounds , Water Pollutants, Chemical , Adsorption , Water Pollutants, Chemical/chemistry , Charcoal/chemistry , Conservation of Energy Resources , Oxidation-Reduction , Electrodes , Phenol , Ferrous Compounds , Hydrogen Peroxide/chemistry
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 119-125, 2024 Mar 30.
Article in Chinese | MEDLINE | ID: mdl-38605608

ABSTRACT

Population aging trend is taking place in our country, and low back pain is a symptom of neuromuscular diseases of concern in the elderly. Accurately analyzing the disease of low back pain is important for both timely intervention and rehabilitation of patients. As a kind of bioelectrical signal, the acquisition and analysis of lumbar electromyography (EMG) signal is an important direction for the study of low back pain. The study reviews the acquisition of lumbar EMG by different types of sensors, introduces the signal characteristics of needle electrodes, surface electromyography electrodes and array electrodes, describes the use of signal algorithms, points out that wireless sensors and the use of deep learning algorithms are the direction of development, and puts forward prospects for its further development.


Subject(s)
Low Back Pain , Humans , Aged , Low Back Pain/rehabilitation , Muscle, Skeletal , Electromyography , Electrodes , Algorithms
8.
Anal Chem ; 96(15): 5852-5859, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38556977

ABSTRACT

A multicolor electrochemiluminescence (ECL) biosensor based on a closed bipolar electrode (BPE) array was proposed for the rapid and intuitive analysis of three prostate cancer staging indicators. First, [Irpic-OMe], [Ir(ppy)2(acac)], and [Ru(bpy)3]2+ were applied as blue, green, and red ECL emitters, respectively, whose mixed ECL emission colors covered the whole visible region by varying the applied voltages. Afterward, we designed a simple Mg2+-dependent DNAzyme (MNAzyme)-driven tripedal DNA walker (TD walker) to release three output DNAs. Immediately after, three output DNAs were added to the cathodic reservoirs of the BPE for incubation. After that, we found that the emission colors from the anode of the BPE changed as a driving voltage of 8.0 V was applied, mainly due to changes in the interfacial potential and faradaic currents at the two poles of the BPE. Via optimization of the experimental parameters, cutoff values of such three indicators at different clinical stages could be identified instantly with the naked eye, and standard precision swatches with multiple indicators could be prepared. Finally, in order to precisely determine the prostate cancer stage, the multicolor ECL device was used for clinical analysis, and the resulting images were then compared with standard swatches, laying the way for accurate prostate cancer therapy.


Subject(s)
Biosensing Techniques , Prostatic Neoplasms , Male , Humans , Luminescent Measurements/methods , Photometry , Prostatic Neoplasms/diagnosis , Prostate-Specific Antigen , DNA , Biosensing Techniques/methods , Electrodes , Electrochemical Techniques/methods
9.
Anal Chem ; 96(15): 6037-6044, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38560885

ABSTRACT

Dopamine (DA), an essential neurotransmitter, is closely associated with various neurological disorders, whose real-time dynamic monitoring is significant for evaluating the physiological activities of neurons. Electrochemical sensing methods are commonly used to determine DA, but they mostly rely on the redox reaction of its o-phenolic hydroxyl group, which makes it difficult to distinguish it from substances with this group. Here, we design a biomimetic nanozyme inspired by the coordination structure of the copper-based active site of dopamine ß-hydroxylase, which was successfully synthesized via a urea-mediated MOF pyrolysis reconstruction strategy. Experimental studies and theoretical calculations revealed that the nanozyme with Cu-N3 coordination could hydroxylate the carbon atom of the DA ß-site at a suitable potential and that the active sites of this Cu-N3 structure have the lowest binding energy for the DA ß-site. With this property, the new oxidation peak achieves the specific detection of DA rather than the traditional electrochemical signal of o-phenol hydroxyl redox, which would effectively differentiate it from neurotransmitters, such as norepinephrine and epinephrine. The sensor exhibited good monitoring capability in DA concentrations from 0.05 to 16.7 µM, and its limit of detection was 0.03 µM. Finally, the sensor enables the monitoring of DA released from living cells and can be used to quantitatively analyze the effect of polystyrene microplastics on the amount of DA released. The research provides a method for highly specific monitoring of DA and technical support for initial screening for neurocytotoxicity of pollutants.


Subject(s)
Dopamine , Mixed Function Oxygenases , Dopamine/chemistry , Phenol , Biomimetics , Copper , Plastics , Pyrolysis , Electrodes , Neurotransmitter Agents , Electrochemical Techniques/methods
10.
Water Sci Technol ; 89(7): 1879-1890, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38619909

ABSTRACT

This study investigated the treatment of wastewater from tomato paste (TP) production using electrocoagulation (EC) and electrooxidation (EO). The effectiveness of water recovery from the pretreated water was then investigated using the membrane process. For this purpose, the effects of independent control variables, including electrode type (aluminum, iron, graphite, and stainless steel), current density (25-75 A/m2), and electrolysis time (15-120 min) on chemical oxygen demand (COD) and color removal were investigated. The results showed that 81.0% of COD and 100% of the color removal were achieved by EC at a current density of 75 A/m2, a pH of 6.84 and a reaction time of 120 min aluminum electrodes. In comparison, EO with graphite electrodes achieved 55.6% of COD and 100% of the color removal under similar conditions. The operating cost was calculated to be in the range of $0.56-30.62/m3. Overall, the results indicate that EO with graphite electrodes is a promising pretreatment process for the removal of various organics. In the membrane process, NP030, NP010, and NF90 membranes were used at a volume of 250 mL and 5 bar. A significant COD removal rate of 94% was achieved with the membrane. The combination of EC and the membrane process demonstrated the feasibility of water recovery from TP wastewater.


Subject(s)
Graphite , Solanum lycopersicum , Water Pollutants, Chemical , Wastewater , Waste Disposal, Fluid/methods , Aluminum , Electrocoagulation/methods , Water , Electrodes , Industrial Waste/analysis
11.
Mikrochim Acta ; 191(4): 228, 2024 04 01.
Article in English | MEDLINE | ID: mdl-38558104

ABSTRACT

A cutting-edge electrochemical method is presented for precise quantification of amitraz (AMZ), a commonly used acaricide in veterinary medicine and agriculture. Leveraging a lab-made screen-printed carbon electrode modified with a synergistic blend of perylene tetracarboxylic acid (PTCA), mesoporous carbon (MC), and Nafion, the sensor's sensitivity was significantly improved. Fine-tuning of PTCA, MC, and Nafion ratios, alongside optimization of the pH of the supporting electrolyte and accumulation time, resulted in remarkable sensitivity enhancements. The sensor exhibited a linear response within the concentration range 0.01 to 0.70 µg mL-1, boasting an exceptionally low limit of detection of 0.002 µg mL-1 and a limit of quantification of 0.10 µg mL-1, surpassing maximum residue levels permitted in honey, tomato, and longan samples. Validation with real samples demonstrated high recoveries ranging from 80.8 to 104.8%, with a relative standard deviation below 10%, affirming the method's robustness and precision. The modified PTCA/MC/Nafion@SPCE-based electrochemical sensor not only offers superior sensitivity but also simplicity and cost-effectiveness, making it a pivotal tool for accurate AMZ detection in food samples. Furthermore, beyond the scope of this study, the sensor presents promising prospects for wider application across various electrochemical analytical fields, thereby significantly contributing to food safety and advancing agricultural practices.


Subject(s)
Carbon , Fluorocarbon Polymers , Perylene , Toluidines , Carbon/chemistry , Perylene/chemistry , Electrodes
12.
Anal Chim Acta ; 1302: 342516, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38580411

ABSTRACT

Conventional plate electrodes were commonly used in electrochemical flow injection analysis and only part of molecules diffused to the plane of electrodes could be detected, which would limit the performance of electrochemical detection. In this study, a low-cost native stainless steel wire mesh (SSWM) electrode was integrated into a 3D-printed device for electrochemical flow injection analysis with a pass-through mode, which is different compared with previous flow-through mode. This strategy was applied for sensitive analysis of hydrogen peroxide (H2O2) released from cells. Under the optimal conditions (the applied potentials, the flow rate and the sample volume), the device exhibits high sensitivity toward H2O2. Linear relationships could be achieved between electrochemical responses and the concentration of H2O2 ranging from 1 nM to 1 mM. The excellent analytical performance of the SSWM-based device could be attributed to the pass-through mode based on the mesh microstructure and intrinsic catalytic properties for H2O2 by stainless steel. This approach could be further successfully extended for screening of H2O2 released from HeLa cells with electrochemical responses linear to the number of cells in a range of 3 - 1.35 × 104 cells with an injection volume of 30 µL. This study revealed the potential of mesh electrodes in electrochemical flow injection analysis for cellular function and pathology and its possible extension in cell counting and on-line analysis.


Subject(s)
Flow Injection Analysis , Hydrogen Peroxide , Humans , HeLa Cells , Hydrogen Peroxide/analysis , Stainless Steel , Electrochemical Techniques , Electrodes
13.
J Cardiothorac Surg ; 19(1): 181, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580985

ABSTRACT

BACKGROUND: A frequent complication of Fontan operations is unilateral diaphragmatic paresis, which leads to hemodynamic deterioration of the Fontan circulation. A potential new therapeutic option is the unilateral diaphragmatic pacemaker. In this study, we investigated the most effective stimulation location for a potential fully implantable system in a porcine model. METHODS: Five pigs (20.8 ± 0.95 kg) underwent implantation of a customized cuff electrode placed around the right phrenic nerve. A bipolar myocardial pacing electrode was sutured adjacent to the motor point and peripherally at the costophrenic angle (peripheral diaphragmatic muscle). The electrodes were stimulated 30 times per minute with a pulse duration of 200 µs and a stimulation time of 300 ms. Current intensity was the only variable changed during the experiment. RESULTS: Effective stimulation occurred at 0.26 ± 0.024 mA at the phrenic nerve and 7 ± 1.22 mA at the motor point, a significant difference in amperage (p = 0.005). Even with a maximum stimulation of 10 mA at the peripheral diaphragm muscle, however, no effective stimulation was observed. CONCLUSION: The phrenic nerve seems to be the best location for direct stimulation by a unilateral thoracic diaphragm pacemaker in terms of the required amperage level in a porcine model.


Subject(s)
Phrenic Nerve , Respiratory Paralysis , Humans , Child , Swine , Animals , Diaphragm , Respiratory Paralysis/etiology , Respiratory Paralysis/therapy , Electrodes , Prostheses and Implants , Electric Stimulation
14.
Int J Mol Sci ; 25(7)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38612501

ABSTRACT

Increased evidence has documented a direct association between Ciprofloxacin (CFX) intake and significant disruption to the normal functions of connective tissues, leading to severe health conditions (such as tendonitis, tendon rupture and retinal detachment). Additionally, CFX is recognized as a potential emerging pollutant, as it seems to impact both animal and human food chains, resulting in severe health implications. Consequently, there is a compelling need for the precise, swift and selective detection of this fluoroquinolone-class antibiotic. Herein, we present a novel graphene-based electrochemical sensor designed for Ciprofloxacin (CFX) detection and discuss its practical utility. The graphene material was synthesized using a relatively straightforward and cost-effective approach involving the electrochemical exfoliation of graphite, through a pulsing current, in 0.05 M sodium sulphate (Na2SO4), 0.05 M boric acid (H3BO3) and 0.05 M sodium chloride (NaCl) solution. The resulting material underwent systematic characterization using scanning electron microscopy/energy dispersive X-ray analysis, X-ray powder diffraction and Raman spectroscopy. Subsequently, it was employed in the fabrication of modified glassy carbon surfaces (EGr/GC). Linear Sweep Voltammetry studies revealed that CFX experiences an irreversible oxidation process on the sensor surface at approximately 1.05 V. Under optimal conditions, the limit of quantification was found to be 0.33 × 10-8 M, with a corresponding limit of detection of 0.1 × 10-8 M. Additionally, the developed sensor's practical suitability was assessed using commercially available pharmaceutical products.


Subject(s)
Ciprofloxacin , Graphite , Animals , Humans , Fluoroquinolones , Carbon , Electrodes
15.
Biosens Bioelectron ; 256: 116277, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38613934

ABSTRACT

The field of biosensing would significantly benefit from a disruptive technology enabling flexible manufacturing of uniform electrodes. Inkjet printing holds promise for this, although realizing full electrode manufacturing with this technology remains challenging. We introduce a nitrogen-doped carboxylated graphene ink (NGA-ink) compatible with commercially available printing technologies. The water-based and additive-free NGA-ink was utilized to produce fully inkjet-printed electrodes (IPEs), which demonstrated successful electrochemical detection of the important neurotransmitter dopamine. The cost-effectiveness of NGA-ink combined with a total cost per electrode of $0.10 renders it a practical solution for customized electrode manufacturing. Furthermore, the high carboxyl group content of NGA-ink (13 wt%) presents opportunities for biomolecule immobilization, paving the way for the development of advanced state-of-the-art biosensors. This study highlights the potential of NGA inkjet-printed electrodes in revolutionizing sensor technology, offering an affordable, scalable alternative to conventional electrochemical systems.


Subject(s)
Biosensing Techniques , Dopamine , Electrochemical Techniques , Graphite , Ink , Printing , Biosensing Techniques/instrumentation , Graphite/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Dopamine/analysis , Electrodes , Equipment Design , Nitrogen/chemistry , Humans
16.
ACS Nano ; 18(16): 10885-10901, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38587876

ABSTRACT

Hypochlorous acid (HClO), as a powerful oxidizer, is obtained from the oxidation of Cl- ions during the electrochemical therapy (EChT) process for cancer therapy. However, the extracellular generated HClO is inadequate to inhibit effective tumor cell death. Herein, manganese-doped potassium chloride nanocubes (MPC NCs) fabricated and modified with amphipathic polymer PEG (PMPC NCs) to function as massive three-dimensional nanoelectrodes (NEs) were developed to enhance the generation of HClO for electrochemical immunotherapy under an alternating electric field. Under an square-wave alternating current (AC) electric field, the generation of HClO was boosted by PMPC NEs due to the enlarged active surface area, enhanced mass transfer rate, and improved electrocatalytic activity. Notably, PMPC NEs upregulated the intracellular HClO concentration to induce robust immunogenic cell death (ICD) under an AC electric field. Meanwhile, the electric-triggered release of Mn2+ effectively stimulated dendritic cells (DCs) maturation. In vivo results illustrated that PMPC-mediated EChT inhibited tumor growth and triggered the promotion of the immune response to regulate the tumor immune microenvironment. Based on the potent antitumor immunity, PMPC-mediated EChT was further combined with an immune checkpoint inhibitor (αCTLA-4) to realize combined EChT-immunotherapy, which demonstrated enhanced tumor inhibition of the primary tumors and an abscopal effect on distant tumors. To summarize, our work highlights the application of electrochemical-immunotherapy technology in tumor therapy.


Subject(s)
Immunotherapy , Manganese , Manganese/chemistry , Mice , Animals , Electrodes , Humans , Electrochemical Techniques , Cell Line, Tumor , Mice, Inbred C57BL , Cell Proliferation/drug effects , Mice, Inbred BALB C
17.
Anal Methods ; 16(16): 2424-2443, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38592715

ABSTRACT

This review summarizes recent developments in amperometric biosensors, based on one-step electrodeposited organic-inorganic hybrid layers, used for analysis of low molecular weight compounds. The factors affecting self-assembly of one-step electrodeposited films, methods for verifying their composition, advantages, limitations and approaches affecting the electroanalytical performance of amperometric biosensors based on organic-inorganic hybrid layers were systemized. Moreover, issues related to the formation of one-step organic-inorganic hybrid functional layers with different structures in biosensors produced under the same electrodeposition parameters are discussed. The systemized dependencies can support the preliminary choice of functional sensing layers with architectures tuned for specific biotechnology and life science applications. Finally, the capabilities of one-step electrodeposition of organic-inorganic hybrid functional films beyond amperometric biosensors were highlighted.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Electroplating/methods , Nanostructures/chemistry , Electrodes
18.
Article in English | MEDLINE | ID: mdl-38613456

ABSTRACT

In the current work, a rapid, selective, and sensitive technique was developed for the detection of Alizarin Red S (ARS) by applying poly leucine modified carbon paste electrode (PLMCPE). Electrochemical impedance spectroscopy (EIS) and Scanning electron microscopy (SEM) were utilized to study the surface morphology of unmodified carbon paste electrode (UMCPE) and PLMCPE. The active surface area for UMCPE and PLMCPE was found to be 0.0012 cm2 and 0.0026 cm2 respectively. The electrochemical response of ARS at UMCPE and PLMCPE was analyzed using cyclic voltammetry (CV) in the potential window of 0.4 to 1.0 V. The cyclic voltammogram obtained for varying the pH of 0.2 M phosphate buffer (PB) solution showed maximum current for the oxidation of ARS at pH 6.5. The electrochemical reaction of ARS was found to be irreversible and adsorption controlled. The effect of variation of concentration of ARS on the oxidation peak current was evaluated using CV and linear scan voltammetry (LSV). A linear relationship between the concentration variation and current was obtained in the linear range of 1.5 µM-3.5 µM and 0.2 µM-5.0 µM for CV and LSV respectively. The limit of detection (LOD) of 0.68 µM for the CV method and 0.29 µM for the LSV method was exhibited by the developed sensor. The simultaneous study of ARS along with tartrazine (TZ) showed good selectivity for ARS. The interferents of foreign molecules showed no effect on the selectivity of the electrode. The applicability of PLMCPE on real samples gave good recovery ranging from 97.46-101.2%; hence, the sensor can be utilized on real samples. The developed sensor has good stability and sensitivity.


Subject(s)
Anthraquinones , Carbon , Tartrazine , Carbon/chemistry , Leucine , Electrodes , Electrochemical Techniques/methods
19.
PLoS One ; 19(4): e0302032, 2024.
Article in English | MEDLINE | ID: mdl-38630787

ABSTRACT

An increasing number of measurement electrodes have been designed to satisfy the demand for high-resolution detection using galvanic logging technology in complex formations. The forward modeling response analysis of logging tools has important guiding significance in the design of galvanic logging tools. Based on a three-dimensional finite element numerical simulation method, we established a forward model of galvanic multi-electrodes in a complex formation. We also designed a symmetrical resistance network model of the formation with equivalent resistance between two electrodes. A symmetrical resistance network was derived using the balanced bridge method. The asymmetrical admittance matrix was extended to a symmetrical extended admittance matrix to realize a convenient calculation of the equivalent symmetrical resistance network in complex formations. Verification of the microcolumn-focused logging tool, with nine electrodes in a simulated standard well, and an evaluation of the degree of invasion in an actual oil well indicate that this calibration method can improve the measurement accuracy of galvanic logging instruments.


Subject(s)
Calibration , Computer Simulation , Electrodes
20.
Sci Rep ; 14(1): 8836, 2024 04 17.
Article in English | MEDLINE | ID: mdl-38632355

ABSTRACT

Imidacloprid is still a widely used neonicotinoid insecticide that is banned in many countries because of the associated environmental risks. Due to the inefficiency of conventional wastewater treatments for pesticide removal, new treatment methods are being investigated. Electrochemical methods, including electrocoagulation (EC), seem to be promising alternatives considering their effectiveness in removing various pollutants from wastewater. The aim of this study was to investigate the effects of electrode material, current density, ultrasound, and operation time on the efficiency of imidacloprid removal from a model solution by EC. The combination of aluminum electrodes and 20 A of applied current for 20 min resulted in total imidacloprid degradation. A simplified energy balance was introduced as a form of process evaluation. Combining ultrasound with EC resulted in 7% to 12% greater efficacy than using only EC.


Subject(s)
Nitro Compounds , Pesticides , Water Pollutants, Chemical , Wastewater , Waste Disposal, Fluid/methods , Neonicotinoids , Electrocoagulation , Electrodes , Aluminum
SELECTION OF CITATIONS
SEARCH DETAIL
...